28
−−
Model Hz/Voltage
Stator coil
Red
-
White Black
-
Blue Black
-
Red
White
-
Light green
Black
-
White
RGV12100 60/120/240
0.11Ω 0.11Ω
------------
0.37Ω
------------
RGV13100T 60/120/208
0.23Ω
------------
0.23Ω
------------
0.23Ω
8-4 STATOR
Disengage connectors on the wires from stator and check the resistance between wires with a
circuit tester, referring to the following specification table.
NOTE : If the circuit tester is not sufficiently accu-
rate, it may not show the values given and
may give erroneous readings.
Erroneous readings will also occur when
there is a wide variation of resistance
among coil windings or when measure-
ment is performed at ambient tempera-
tures different from 20
℃
(68
°
F).
8-3 AC SWITCH (NO-FUSE BREAKER)
Check continuity between each of 2 terminals at the back side of AC switch (no-fuse breaker)
while it is mounted on the control panel.
Normally, there is continuity between each of the 2 terminals when the breaker is ON, while no
continuity when the breaker is OFF.
RGV13100TRGV12100